Our Temp-Plate Insertion Panels are a direct replacement for the open tank heat exchangers supplied by McMaster-Carr. These flat-panel heat exchangers can be placed in open tanks to heat or cool their contents by transferring heat from liquid or steam that flows through passageways in the panel. Pipe connections are located above the fluid level, so the heat exchangers can be removed without emptying the tank.
We offer the Temp-Plate Insertion Panels in 316 stainless steel; this allows for a more corrosion resistant open tank heat exchanger.
This Temp-Plate panel is a direct replacement for the part #3603K43 supplied by McMaster-Carr.
Surface Area
|
Flow Cap. |
Max psi |
Temp. Range |
Pipe Size (Inlet)
|
Thread Type (Inlet) |
Gender (Inlet) |
Pipe Size (Outlet) |
Thread Type (Outlet) |
Gender (Outlet) |
Overall Ht.
|
Wd. |
Panel Ht. |
Replaces Part Number |
Cost |
12.2 sq.ft. |
18 gpm |
250 |
-20°F to 400°F |
1 |
MPT |
Male |
3/4 |
MPT |
Male |
34 1/4" |
35" |
22" |
3603K43 |
|
Plating and Anodizing is one of the industries you can find Temp-Plate Insertion Panels being used; check out the video below for more information!